romex cable above 3 stories | Information by Electrical …
Sep 17, 2004 · Re: romex cable above 3 stories Ryan is correct. The only way (under the IBC) that this building could be built over 5 stories would be with type I construction. NM is ruled …
Romex and SER ampacities. | Information by Electrical …
May 12, 2021 · Correct me if I'm wrong; romex(nm) wiring is limited to the 60 degree column in table 310.16. So a 60 amp hot tub's disconnect could not be fed with 6/3 romex, but the load …
12-4 Romex with Dual Neutrals | Information by Electrical …
Jun 10, 2005 · Re: 12-4 Romex with Dual Neutrals It does save on the labor over running two 12/2 cables in parallel. If you are wiring a 3-way circuit that requires 4 wires such as needing …
Garage romex protection | Information by Electrical Professionals …
Mar 29, 2010 · Right Charlie. How many times do we hear guys here saying how exposed romex is subject to physical damage. Their solution is to sleeve it in pvc or nonmetallic flex neither of …
Romex | Information by Electrical Professionals for Electrical ...
Sep 6, 2013 · In the code book it says that you can install Romex if permitted as a Type 3, 4 or 5 building, but if it is permitted as a type 1 building you can not install Romex. Although IF the …
Romex in conduit | Information by Electrical Professionals for ...
Jun 26, 2006 · You can get alot more building wires in a conduit than type NM cable. I am not sure but it seems like you can only get 3-12/2 romex's in a 3/4" EMT conduit. The most you …
Flood "Damaged" Romex? | Information by Electrical Professionals …
Oct 22, 2009 · Not all "Romex" has paper-filler and the paper-filler alone does not necessary cause problems. If the moisture is driven out on the long run and instead if just evaporating it …
Romex in metal studs | Information by Electrical Professionals for ...
Feb 16, 2004 · Re: Romex in metal studs Bob those work great with 4 sqs. but for the most part pvc bracket boxes are used and when there are 2 gangs and up you have to brace them to …
Romex for DC run | Information by Electrical Professionals for ...
Apr 22, 2019 · Legal or not? Code reference if applicable. Sent from my iPhone using Tapatalk Legal,no prohibition. Get the NM cable from Canada; they have it with red and black, no white. …
Romex in Basement | Information by Electrical Professionals for ...
Mar 16, 2017 · At this residence, Romex (10/2, 12/2 & 14/2) can be found stapled to the floor joists in virtually every direction (parallel, perpendicular, and across at angles). Some of the …