FPD GC detector for sensitive sulfur and phosphorus analysis
The Agilent Flame Photometric Detector (FPD) Plus uses the latest photomultiplier technology, proprietary deactivation treatments, and other design enhancements for sensitive and selective GC detection of organic compounds containing sulfur or phosphorus.
Flame Photometric Detector (FPD) for GC | Agilent
Flame Photometric Detector (FPD) Supplies for GC In 2005, Agilent released an improved FPD with minimum detectable levels (MDL) of 3.6 pg/s for sulfur and 60 fg/s for phosphorus. This is more than a 5 times improvement for sulfur.
Volatile Sulfur in C2, C3, C4 monomers and LPG Analyzer by FPD ASTM D6228 •If the matrix is reasonably simple and sulfur levels are in the low ppm to 100 ppb range then the FPD will usually be a good choice.
Flame Photometric Detector - FPD The FPD uses one of two available band pass filters over a photomultiplier tube (PMT) to selectively detect compounds containing sulfur or phosphorus as they combust in the hydrogen flame.
FPD - Flame Photometric Detector - SRI Instruments Europe …
The Flame Photometric Detector can detect sulfur compounds, such as H 2 S or SO 2, down to about 200 ppb and phosphorus compounds to 10 ppb. While not 100% selective, the FPD is 100,000 times more sensitive to sulfur and phosphorus compounds than hydrocarbons.
Gas Chromatography Detector (Type of GC Detectors)
Flame Photometric Detector (FPD) It is capable of detecting phosphorus (P) compounds, sulfur (S) compounds, and organic tin (Sn) compounds. The Flamephotometric ( FPD) is highly selective as it detects element-specific light emitted within a hydrogen flame.
iConnect™ Flame Photometric Detector (FPD) for TRACE™ 1300 …
The Thermo Scientific™ iConnect™ Flame Photometric Detector (FPD) has an extended operating temperature range and dual wavelength capabilities to further expand its applicability. This detector is for use with Thermo Scientific™ TRACE™ 1300 and 1600 Series GC systems.
D6228 Standard Test Method for Determination of Sulfur …
Dec 5, 2023 · 1.1 This test method covers the determination of individual volatile sulfur-containing compounds in gaseous fuels by gas chromatography (GC) with a flame photometric detector (FPD) or a pulsed flame photometric detector (PFPD). The detection range for sulfur compounds is from 20 to 20 000 picograms (pg) of sulfur.
in which the FPD-2014, with its redesigned FPD nozzle to accommodate both packed and capillary columns, was used along with optimization of the flow ratio of the combustion gases to investigate the reduction of quenching in analysis of a trace amount of a sulfur compound in gasoline. We investigated the changes induced in the sensitivity
Install the FPD 21 Install the Flow Module 23 Install the Detector Board 24 Close the Lid and Install the Covers 27 Restore the GC to Operating Condition 28 The G3348 kit contains a flame photometric detector (FPD) for your Agilent 6850 Series II gas chromatograph (GC).