#403 – Fire Department Connections: A Guide to FDC …
Jan 27, 2022 · Many buildings have a fire department connection (FDC) that allows firefighters to pump water into the building’s fire sprinkler and standpipe systems. If you are a building owner or their designated representative, you are responsible for maintaining this life-saving equipment.
The FDC: What Does it Stand for and What Does it Do?
May 28, 2020 · The FDC is the fire department connection portion of a fire sprinkler system or standpipe system. Its role in ensuring the effectiveness and success of a fire sprinkler system to suppress a fire is pivotal.
Understanding the Use of Fire Department Connections
Jul 11, 2017 · There are two primary methods in which hoselines can be connected to the fire department connection: 1) a forward lay supply hoseline operation or 2) a reverse lay supply hoseline operation.
Hydrant Valves | Fire Department Connections | FDC Connections …
Our Water Handling Equipment and FDC Connections include: Intake valves, Gate valves, Hydrant Storz, Storz & Threaded Adapters, Drafting & Suction Equipment. Looking for the best connection? Look no further than Harrington, Inc.
Fire Department Connections: A Complete Guide - QRFS
A complete FDC installation includes the pipe that leads from the FDC to the system and a check valve that ensures one-way water flow. But the fire department connection itself has these main parts: Swivels connect fire hoses to the FDC’s inlets and allow hoses to rotate.
Fire Dept. Connection according to NFPA 14
Aug 28, 2019 · Valves for FDC: Isolation valves shall not be permitted. A listed check valve shall be installed in each fire department connection as close as possible to fire department connection inlets, and shall be located in accessible location with automatic drain valve where subject to …
Is Automatic Drain Required for Remote FDC? - meyerfire.com
Jan 29, 2025 · In an area subject to freezing, we have a remote FDC that supplies a riser room at the same level. The feed is through underground pipe. Is the base of the FDC required to have an automatic drain similar to what's at the base of dry barrel fire hydrants? If not, how are these FDC's typically drained after use? Sent in anonymously for discussion.
Fire Department connection according to NFPA 13
Aug 28, 2019 · What is Fire department connection (FDC)?! A connection through which the fire department can pump supplemental water into the sprinkler system, standpipe, or other water-based fire protection systems, furnishing water for fire …
What Does FDC Stand For? - Vanguard
Nov 19, 2021 · An FDC is a connection through which a fire department can pump water into the sprinkler system, standpipe, or other system within a building. This provides additional water to supplement the building’s existing water supplies, which is …
FDC Connections | Fire Department Connections
The FDC connects to an inlet pipe behind the building’s wall, linking with the existing sprinkler system or standpipe riser. Additionally, FDCs incorporate a check valve to prevent water backflow and plugs to cover inlet valves, safeguarding against pipe …