Urinal - The Building Code Forum
Mar 27, 2024 · g. Single-user unisex facilities shall include a urinal in food service establishments or any establishment that sells alcoholic beverages for on-site consumption. A single user facility with a WC and Urinal installed will only count as one …
Are Urinals Required in Unisex Restrooms? - The Building Code …
Nov 13, 2023 · For utmost privacy we recommend modesty screens between each urinal, and floor-to-ceiling walls and doors for all stalls. The third option affords all users the greatest privacy, but multiple toilet rooms with locking doors can make the project more expensive.
Urinal required in a single occupancy toilet for "B" occupancy?
Aug 16, 2011 · We have a plan checker that is insisting that because the California Plumbing Code table 422.1 indicates that a urinal is required for 1-100 men for a B occupancy that even when a single room occupancy toilet room is allowed to serve both employees and customers that this room also is required to have a urinal.
Urinal Requirement - The Building Code Forum
Apr 12, 2021 · SH225 is correct single use toilets shall be "all Gender". If you want the restrooms to be gender specific, you need two fixtures. (two toilets in the Women's, and a Toilet and Urinal in Men's) A "B" occupancy also has a minimum requirement of a urinal, per 2019 CPC TABLE 422.1. Alcohol Beverage Control also has a urinal requirement.
Urinals in Single User Restrooms | The Building Code Forum
Oct 25, 2009 · I have read many items on this including the BU_17-01-01.pdf from the DSA, HSC 118600 on Single User Restrooms, an Iapmo interpretation and we have not found where the text allows an elimination of the urinal. Female water closets must equal W/C and urinals required in a men's room, but this does not apply when it is a single user facility in ...
Minimum Required Size of Non-ADA Toilet Stall
Nov 25, 2009 · 405.3.1 Water closets' date=' urinals, lavatories and bidets. [/b']A water closet, urinal, lavatory or bidet shall not be set closer than 15 inches (381 mm) from its center to any side wall, partition, vanity or other obstruction, or closer than 30 inches (762 mm) center to center between adjacent fixtures. There shall be not less than a 21 ...
Urinal flushometer [Vacuum Breaker] - The Building Code Forum
Feb 11, 2013 · Re: Urinal flushometer [Vacuum Breaker] Thanks for the replies. It's a solid slab of granite on the wall, so the only real option would be to go back to the original urinal as opposed to raising the water height. It's a shame as the urinals he got are really amazing looking, and the original ones are nothing special.
ADA Urinals - The Building Code Forum
Dec 1, 2017 · Where no more than one urinal is provided in a toilet room or bathing room, the urinal is not required to be accessible. "Exception 4—The IPC permits urinals to be substituted for water closets to a maximum of 67 percent in each toilet room (see Section 419.2 of the IPC). Exception 4 states that if only one urinal is provided
Partitions between fixtures - 2006 IBC & IPC - The Building Code …
Jan 24, 2011 · Now take a look at the urinal screen's size especially the distance from the floor to the bottom and to the top of the urinal screen. Manufacturers do not make the urinal screen tall enough. Now look at the requirement for how far the urinal screen must project beyond the urinal basin. It takes a 24" wide urinal screen to comply.
Urinal Vacuum Breakers - The Building Code Forum
Oct 6, 2010 · 2009 UPC. We have a plumbing contractor proposing to install a 90 deg turn metering push button valve on a urinal. The valve is a Pasco, part # 21810. This valve does not appear to have a vacuum breaker on it. Has anyone ever seen this valve installed? I looked into the 2006 IPC to see how it...