BXUVC.F817 - Fire Resistance Ratings - A/D Fire Protection …
Dec 6, 2014 · BXUVC.F817 - Fire Resistance Ratings - A/D Fire Protection Systems. You also want an ePaper? Increase the reach of your titles. YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Influx of Fire-Rated Steel Designs Without Load Restriction
Dec 16, 2016 · These design listings, together with the ULC design listings that are free from load restriction, such as ULC F817, F906, F919, N815 and N816, provide many more options and greater flexibility in the selection of fire-rated designs for steel floors and roofs.
The table on the following pages lists the ULC fire rated assemblies that include Vulcraft composite deck profiles. This summary table is provided to assist in identification of assemblies to meet specific project requirements.
By entering these CCNs in the UL or ULC Category Code search field, you will find all the Fire Resistance Designs listed for that specific conformity – either US, Canadian or both.
ULC design F906 allows minimum 83mm NWC. Aforementioned based solely on Southwest and A/D product lines. ULC design F906 does not have a OWSJ in the design; reference ULC Rules of Transfer to transfer components.
ULC F817. ULC F906. Southwest® SFRM Series. UL Design Flow Chart – Concrete/Steel Deck. Southwest Type 5- MD. Southwest Type 7- GP. Southwest Type 7- HD. Quick Links. General Notes * Also certified for use in Canada (CAN/ULC -S101) August 2019. Concrete Slab. Precast Hollowcore. UL J957* S739. N791. Cast-in Place.
Nov 19, 2010 · We have updated your Fallow-up Service, (FL'S) Procedure, and Listing Card under the above file number. We have also revised ULC design F816, F817, 904 and 906 10 include the above new deck profiles You should expect to receive the FUS Procedure in the near future. Please review these documents carefully for errors and omissions.
ULC AND cUL SPRAY-APPLIED FIRE-RATED DESIGNS 1. Introduction Where fire-resistance ratings apply, steel-framed building structures in modern-day construction are usually protected by means of spray-applied or membrane protection. Spray-applied fire-resistive materials (SFRM) have traditionally been referred to as cementitious and
CD75-150 | CD75-150 CL Galvanneal – Agway - Agway Metals Inc.
Agway CD deck sections are listed in the following ULC floor assemblies: F817; F904; F906. Bundled deck produced from either Galvanneal or G90 Galvanized coated steel is susceptible to storage stain when exposed to the elements.
UL 817 | UL Standards & Engagement | UL Standard
Feb 24, 2025 · 1.1 This standard specifies the requirements for cord sets and power-supply cords employing molded-on or assembled-on fittings, rated 600 V maximum, and intended for use in non-hazardous locations in accordance with the National Electrical Code, ANSI/NFPA 70.