12-4 Romex with Dual Neutrals - Mike Holt's Forum
Jun 10, 2005 · Has anyone used 12-4 or 14-4 NM cable with two neutrals? I've seen it advertised for running two AFCI circuits. I was wondering if it is cost effective?
Romex | Information by Electrical Professionals for Electrical ...
Sep 6, 2013 · In the code book it says that you can install Romex if permitted as a Type 3, 4 or 5 building, but if it is permitted as a type 1 building you can not install Romex. Although IF the building can be a type 3,4 or 5 building you can in fact install Romex. Can someone interpret this code 334 for me?
Romex and SER ampacities. | Information by Electrical …
May 12, 2021 · As far as SER it seems that #4 is the best choice for a 60 amp feeder cable, (if we can use 75 degrees) since it is usually readily available, and #4 romex would be severe overkill.
Romex in conduit | Information by Electrical Professionals for ...
Jun 26, 2006 · I was wondering if there is any restriction to installing romex wire in conduit? The code states you can do it for physical protection. So is there any ruling against running it in conduit when there is no need for protection? Thank you for your help
How much romex will it take? | Information by Electrical …
Jan 25, 2011 · Benton, the best thing to do is, is and actual take off from your print. If it's a paper print, buy a scale wheel to measure home-runs. If its digital, buy software where you can do on line take offs. Most assemblies have 15' of romex allowance. Count the devices and multiply. Measure the distance for home-runs.
Romex in metal studs | Information by Electrical Professionals for ...
Feb 16, 2004 · Re: Romex in metal studs Have wired many of metal stud house in romex.They are a bit of a pain but nothing wrong with them.Be sure to brace anything over single gang boxes with a piece of 2x 4
Romex in Basement | Information by Electrical Professionals for ...
Mar 16, 2017 · My question is regarding whether or not the romex in the basement of a residence is in compliance with code. At this residence, Romex (10/2, 12/2 & 14/2) can be found stapled to the floor joists in virtually every direction (parallel, perpendicular, and across at …
Romex for DC run | Information by Electrical Professionals for ...
Apr 22, 2019 · Legal or not? Code reference if applicable. Sent from my iPhone using Tapatalk Legal,no prohibition. Get the NM cable from Canada; they have it with red and black, no white. I call it DC Romex. See: 210.5(C)(2), 250.162 and 250.164, 410.134, and solar if applicable.
romex cable above 3 stories | Information by Electrical …
Sep 17, 2004 · this is a question whether anyone has had a project where they installed type nm cable in a building above 3 stories. we are looking at value engineering a 6 story extended-stay motel. we are interpreting that the change in art. 334.12 in the 2002 nec will allow this. also give me any pros and...
Using 14-4 Romex Cable | Information by Electrical Professionals …
Nov 16, 2011 · Where can I buy 14-4 Romex cable? It would have a total of 5 conductors (black, white, red, blue, and ground). There are a lot of times where the extra blue wire would be helpful, such as running a hot, neutral, and two travelers in a …