Point-of-care (POC) hemoglobin A1c (HbA1c) testing has advantages over laboratory testing, but some questions have remained regarding the accuracy and precision of these methods. The accuracy and the precision of the POC Afinion™ HbA1c Dx test were investigated.
Hemoglobin A1c Measurement Using Point of Care Testing
Mar 2, 2020 · Hemoglobin A1c (HbA1c) measurements can be performed using point of care testing (POCT) devices, and comparing POCT devices with high-performance liquid chromatography (HPLC) is essential.
A Comparative Evaluation of HbA1c Measurement Methods and …
In this study, we assessed the correlations between hemoglobin A1c (HbA1c) measurements obtained using three different diagnostic methods, namely reversed-phase cation-exchange chromatography, high-performance liquid chromatography, and lateral flow immunoassay (LIFA) with an AnyLab F instrument.
Comparing HbA1C by POC and HPLC - PubMed
Sep 4, 2018 · Objective: Point-of-care (POC) Hemoglobin A1C (HbA1C) testing is frequently used to assess glycemic control in diabetes management. Studies are lacking on the comparison of POC with high performance liquid chromatography (HPLC) when the POC HbA1C is ≥ 14%.
Comparison of Point-of-Care and Laboratory Glycated …
The objectives of this study were (1) to compare same-visit POCT-HbA1c using the Cobas b 101 POC-HbA1c measurements and Lab-HbA1c, and (2) to define the relationship between TIR, GV, and HbA1c levels (POCT-HbA1c versus Lab HbA1c) as assessed by last 90 days of ambulatory glucose profile (AGP) metrics obtained reports through the LibreView web ...
Comparison of a point-of-care analyser for the determination of …
Aug 1, 2017 · This study compared the performance of the automated Quo-Test POCT device (EKF Diagnostics), which uses boronate fluorescence quenching technology, with a laboratory based High Performance Liquid Chromatography (HPLC) method (Biorad D10) …
HbA1c-testing: Evaluation of two point-of-care analysers
We prospectively tested two widely used POCT methods to measure HbA 1c, namely Afinion™ AS100 Analyzer (Axis-Shield, Oslo Norway) and DCA Vantage™ Analyzer (Siemens Healthcare Diagnostics, Tarrytown NY, US) in venous samples of 100 patients.
DIFFERENCE IN GLICATED HEMOGLOBIN LEVEL BETWEEN …
Apr 13, 2019 · Ion exchange-high performance liquid chromatography (HPLC) and boronate affinity use first concept. Ion exchange-HPLC is reference method in most of clinical laboratorium. Point of care...
Evaluation of a HbA1c point-of-care analyzer - ScienceDirect
Jul 1, 2015 · B-Analyst® is a POCT analyzer designed to control diabetes in a query to be run by nurses not accustomed to handling laboratory equipment. Prior to such use step, we have proposed evaluation by laboratory personnel compared to the gold standard HPLC technique.
(PDF) Comparison of a Point-of-Care Analyser for the Determination of ...
Apr 1, 2017 · Aims: As the use of Point of Care Testing (POCT) devices for measurement of glycated haemoglobin (HbA1c) increases, it is imperative to determine how their performance compares to...