NM cable in conduit | Information by Electrical Professionals for ...
Jul 17, 2020 · Hi , I know it is in the NEC that you can't use NM cable installed in conduit as a "Wiring Method" . It can be ran in conduit for protection from physical damage , like up a masonry wall in an unfinished basement or in a conduit sleeve passing through a masonry wall . Can somene find that in...
Securing NM wires entering service panel | Information by …
Feb 22, 2018 · Is it always required to secure NM wire within 12” if entering a service panel? Specifically, if the wires are coming through holes in joists directly above the panel where there’s 12” or less between the holes in the joists and the cable clamp entering the panel. if …
Type NM cable temp. rating | Information by Electrical …
Oct 13, 2003 · What is the temperature rating of the conductors in type NM cable? Seems like I heard somewhere that it is 90C. I have a fixture that requires 90C conductors and I need to know if I can run NM cable to it.
NM wire and 60 degree ampacity limit | Information by Electrical ...
Jan 22, 2020 · Old NM cable without the -B suffix is truly 60C designed AFAIK. Once they created NM-B you still had to base your absolute minimum ampacity from 60 C ampacity table, but could and still can make any adjustments starting with 90C ampacity values.
Current Rating Using #8/3 NM-B Conductor - Mike Holt's Forum
May 12, 2021 · #8/3 NM-B wire is rated for 90°C temperature however the NEC current carrying capacity limits its rating based on 60°C. This is based on the typical 60°C rating for residential applications. My question is if I am using it on equipment that has terminal temperature ratings of 75°C or 90°C, am...
Exposed NM cable in kitchen cabinets | Information by Electrical ...
Aug 22, 2010 · Do you wire these using MC cable, or bare NM? Do you put the NM straight into the surface-mounted box, or through the cabinet first? (If you go straight into the box, how do you handle clamping requirements?) Some electricians I've worked with use a bit of flexible conduit between the box and the wall, or the box and the hole in the cabinet back or base.
NM cable and the outdoors - Mike Holt's Forum
Mar 29, 2021 · I agree with the NM cable and the THHN conductors not allowed in wet location, and the AHJ has every right to dissect the OP installation and decide whether or not it is compliant.
Securing Type NM Cable | Information by Electrical Professionals …
Senior Member Oct 25, 2005 #6 Re: Securing Type NM Cable the wire itself is rated at 90 degrees for the purpose of derating, not 60 degrees
NM cable in nonmetalic flex - Mike Holt's Forum
Apr 19, 2006 · Does the NEC prohibit the use of NM cable in liquidtight flexible nonmetallic conduit? An example would be using NM cable from a disconnect to an air conditioning unit.
NM-B in conduit? | Information by Electrical Professionals for ...
Jun 21, 2014 · The only code against NM in conduit is the conduit/raceway can't be outside in a wet location. The code now considers the inside of a raceway in wet locations as a "wet location".