Fluo-3 - Wikipedia
Fluo-3 is a fluorescence indicator of intracellular calcium (Ca 2+), developed by Roger Y. Tsien. [1] It is used to measure Ca 2+ inside living cells in flow cytometry, and confocal laser scanning microscopy using visible light excitation (compatible with argon laser sources operating at …
Fluo-3 Calcium Indicator | Thermo Fisher Scientific - US
The Ca 2+ indicator fluo-3 (Figure 1) was developed by Tsien and colleagues for use with visible-light excitation sources in flow cytometry and confocal laser-scanning microscopy. Since being introduced in 1989, fluo-3 imaging has revealed the spatial dynamics of many elementary processes in calcium signaling.
Fluorescent Ca2+ Indicators Excited with Visible Light—Section 19.3 ...
Visible light–excitable Ca 2+ indicators offer several advantages over UV light–excitable indicators: The Ca 2+ indicator fluo-3 (Figure 19.3.1) was developed by Tsien and colleagues for use with visible-light excitation sources in flow cytometry and confocal laser-scanning microscopy.
Fluo-3, fluo-4 and their derivatives all exhibit large fluorescence intensity increases on binding Ca2+. Unlike the ultra -violet light–excited indicators fura-2 and indo-1, there is no accompanying spectral shift.
Fluo-3, AM, Calcium Indicator - Thermo Fisher Scientific
The cell-permeant dye fluo-3 AM is a visible lightexcitable, high affinity Ca2+ indicator. It is available in 1 mg amounts (F-1241), as a 1 mM solution (F-14218), in a high-throughtput screening amount (F-14242) and in our Fl.
Chemical Calcium Indicators - PMC
Fluo-4 is essentially a brighter, more photostable derivative of fluo-3. Its Ca 2+ affinity is a little lower (K d ~345 nM) and its absorption maximum is shifted ~12 nm compared to fluo-3, making it more suitable for 488 excitation using an argon laser ( 43 - 45 ).
Fluo-3 - an overview | ScienceDirect Topics
Fluo-3 is a calcium sensor that utilizes fluorescein as a fluorescent tag, with excitation and emission wavelengths near 505 nm and 530 nm, respectively. It has a 325 nM affinity for Ca2+ and shows a 40-fold increase in emission intensity upon calcium binding.
Mag-fura-2 (Table 1) can be used as a magnesium indicator or low afinity calcium indicator. We also provide a selection of fluorescent indicators for chloride and zinc (page 5), as well as pH indicators (pages 6-7).
Fluo-3 fluorescence, 70 123632-39-3 - MilliporeSigma
Fluo-3 and related molecule Fluo3/AM are used as a fluorescence indicator of intracellular calcium (Ca2+). Fluo-3 may be use for flow cytometry and confocal laser scanning microscopy using visible light excitation (compatible with argon laser sources operating at 488 nm).
Comparing Ca2+-Sensitive Dyes Fluo-3 & Fluo-4 with the FLIPR ...
This application note describes the comparison of using fluo-3 & fluo-4, loaded into M1-transfected CHO-cells and how the FLIPR System is used to measure the calcium response to carbachol activation.