Opinions WeilMcLain GV90 Series Boilers? - Heating Help
The GV90 is kinda like the **** child, of a cast iron and modcon boiler, I don't think the advantages outweigh the additional complexity. In your case it sounds like a good cast iron boiler might be the way to go, but don't forget a boiler protection strategy, it can be as simple as a thermostatic valve to recirc supply into the return to ...
GV90+ continually turns on and off ~ ever few minutes
Hello. I have a Weil McLain GV90+ Furnace. New about 5 years ago. It won't stay running. It fires and gets the water temp up to about 185 then shuts off. The water temp drops after about a minute or two to about 155 then fires again. The pumps are continually running calling for water to be circulated to the heating zones throughout the house.
GV90+4 Installation — Heating Help: The Wall
I am replacing a discontinued Weil Mclain VHE, Series 3 boiler, 100,000 BTU. It is a LP-fueled, 2-zone residential baseboard hot water system. My plan is to leave the existing loops in place and replace the VHE with the GV90+4 boiler, 84,000 BTU.
Gv90+ DHW — Heating Help: The Wall
Replaced a leaking UB90 HX that was 16 yrs old with a GV90+4. I installed this unit myself using the 1.25" headers with 1" pipe, for the primary and secondary loops. I have 4 pumps on the header, 3 that feed the copper slatfin, and one going to the Amtrol indirect hot water heater.
Well McClain GV90+4 Takes To Long To Heat Up Rooms
Jan 18, 2025 · GV90+ can have poor performance for several reasons. High limit is set to low and the boiler is not getting hot enough to heat the rooms; Air in the radiators or baseboards. if there is air in the system then the heat transfer medium (Water) can not move as much heat. Sludge or other debris is blocking the water flow in the pipes.
Weil McLain GV90 no flame because of clogged condenser drain?
Nov 26, 2021 · I have a Weil McLain GV90+4 LP conversion that stopped delivering heat, of course it had to happen just in time for Thanksgiving. Symptoms were blower and circulators run, sounds of water gurgling but the flame won't come on.
GV-90+ Ignition problems — Heating Help: The Wall
4. How much gas should a Weil-McLain GV90-4 burn while on? The manual says that the pipe capacity should be 140 CFH, but that may have a wide margin compared to the actual consumption. Mine uses between 90 and 102 to the best I could measure. 5. For how long should the fire burn at one time?
Gv90 short cycling be and slow to heat house - Heating Help
New install. Gv90+5. Baseboard. Two stories. 3 zones. 2000sq ft. Didn't notice lack of heating until recent crazy cold temps. House normally at 65. Set to 70 and after a few hours it was only at 68. Noticed boiler would cycle on and off but thought it was just the circulator / energy savings routine. Watched it go through a cycle. Start at 150 ...
GV90+ or IBC HC series (Help me choose)
One contractor is keen to install a Weil-Mclean GV90+, which I gather is an old school boiler that's increased its efficiency to over 91% by adding a condensing unit. He doesn't like wall hung units because "they only last 10 years and need more repairs."
Outdoor Reset - how to install on WM - GV90 - Heating Help
What parts do I need to install and program ODR on. Weil McC. Gv90-6?? I have a Taco 6 zone controller running 2 taco circulators.