Use of Traps in GC - Peak Scientific
Although these generators can be used to supply the GC directly, for extra peace of mind, traps can be used as outlined by the major GC manufacturers. Most end users will use a carrier gas trap, which removes a combination of hydrocarbons, moisture and oxygen.
Purge and Trap Overview - Teledyne LABS
Purge and Trap gas chromatography is a method of removing volatile organic compounds from a solid or liquid sample. Once purged, trapped and desorbed, the sample is separated in a gas chromatography instrument.
GC Inline Gas Purifiers & Filter – Big Universal Trap - Agilent
Agilent inline gas purifiers (traps or filters) remove common contaminates such as oxygen, moisture, and hydrocarbons from GC carrier and detector gases. Our GC gas purifiers are available in different sizes and configurations such as combination gas traps that remove moisture, oxygen, and/or organics with a single trap.
Fundamentals of Purge & Trap - Teledyne LABS
The sample is purged with inert gas, causing VOCs to be swept out of the sample. The VOCs are retained in an analytical trap, which allows the purge gas to pass through to vent. The VOCs are then desorbed by heating the trap, injected into the GC by backflushing the trap with carrier gas, and separated and detected by normal GC operation. Purging
Split-Vent Traps: GC's Dirty Secret - Chromatography Online
Oct 1, 2015 · Split injection vent traps are a necessary adjunct to high-performance gas chromatography with open-tubular columns. These traps protect carrier-gas regulation components in the short term from performance-degrading perturbations because of injection, and in the long term from accumulation of sample residues that also can affect performance.
Traps for GC gases - Chromatography Forum
Jun 16, 2005 · If I am buying Ultra High Purity gases (He, H2, air) for use with my GC-FID, is it still necessary to put O2, H2O, etc. traps in the lines? Which gas lines is it most important to have the traps on? And what traps would be recommended at a minimum?
Gas Purifiers and Traps | Fisher Scientific
Chemical traps and gas purifiers to remove moisture, oxygen, hydrocarbons, or other contaminants from GC gas supply lines; includes ECD and split vent traps, indicating traps, rechargeable traps, S-traps, gas purifier modules, and replacement parts.
SIS GC Cryo Traps - Theory of Operation - sisweb.com
SIS GC Cryo Traps - Theory of Operation (This Page) New Programmable Cyro-cooling and heating trap for the Cryo-focusing of volatiles and semivolatiles at the head of GC capillary columns.
Fitted with 1/8-inch od Swagelok fittings, the trap is installed directly between the gas line regulator and the gas inlet on the back of the instrument. Since the trap body is constructed of stainless steel, it can be conditioned or regenerated at …
CryoFocus-4 ColdTrap for Gas Chromatography
Cryogenic cold trapping is frequently used for narrowing the chromatographic band and improving the detection limit in Gas Chromatography. The cryotrap uses LN2 or CO2 for cooling, due to our low thermal mass the cooling is really fast.