
ENA Type Test Verification Report Register | Browse Products
Product ID Manufacturer Type Model Output ≤50kW >50kW Not Type Tested (as per G59) Phase ENA Standard Entered Download; ASJA.001: Asja: Domestic CHP: TOTEM 20
A2-3 Compliance Verification Report –Tests for Type A Inverter Connected Power Generating Modules – test record 1. Operating Range: Five tests should be carried with the Power Generating Module operating at Registered Capacity and connected to a suitable test supply or grid simulation set. The power supplied by the primary
ENA Engineering Recommendation G100 Issue 2 Amendment 2 2023 Manufacturer’s CLS Product Information This form is available in a Microsoft Word version from the ENA’s website.
ENA Engineering Recommendation G98/NI Issue 1 2019 Page 1 1 Form C: Type Test Verification Report Type Approval and Manufacturer declaration of compliance with the requirements of G98/NI. This form should be used when making a Type Test submission to …
ENA Type Test Register - ENA Eng
The majority of data and documents on the site are available to all users without log in and an account is not required. Manufacturers can choose to flag uploaded documents as 'restricted' and these are only available to registered Distribution Network Operator (DNO) or Independant Distribution Network Operator (IDNO) users or users from the manufacturer of the device.
ENA Type Test Verification Report Register | HELP - ENA Eng
All Users This page enables access to all data available in the system and is available to all site visitors. Manufacturers and system administrators can add and/or maintain product data on this page if they have logged in. Click the Log Out button to return to the login page.
ENA Engineering
Welcome to the ENA Engineering web portal. This page gives access to the following web applications: The National Equipment Defect Reporting Scheme (NEDeRS ®) The ENA Document Catalogue () The ENA Product Assessment System () The National Gas Incident Site (NGIS) is no longer managed by the ENA.It was replaced with the Gas Transporter Incident Notification Service (GTINS) on 1st Jan 2025.
- [PDF]
ENA Engineering
%PDF-1.3 %¡³Å× 1 0 obj > endobj 2 0 obj > endobj 3 0 obj > endobj 4 0 obj >>>/MediaBox[ 0 0 592.32 844.32]/Contents 6 0 R /Rotate 0>> endobj 5 0 obj >stream ...
Engineering Recommendation G99 Form A2-3 Type A Power Generating Modules 2. Power Quality — Harmonics. energynetworks association For Power Generating Modules of Registered Capacity of less than 75 A per phase (i.e. 50 kW) the test
2. Power Quality – Harmonics: For Power Generating Modules of Registered Capacity of less than 75 A per phase (ie 50 kW) the test requirements are specified in Annex A.7.1.5These tests should be carried out as specified in BS EN 61000. 3-12 The results need to comply with the limits of Table 2 of BS EN 610003-12 for single phase equipment -