Drain Pipe Perforations - Up or Down? 1 - Eng-Tips
Dec 1, 2002 · We are installing a 150mm diameter perforated pipe within the French drain. Perforations of 8mm diameter; 4 rows of holes all in same half section of pipe. Infill is +10 to –20mm stone although contractor will ask soon to put in 20-40mm stone above the drainage pipe - availabiity of materials.
storm pipe minimum slope??? - Storm/Flood engineering - Eng-Tips
Apr 5, 2007 · Normally I will determine the min. slope which will produce a velocity of 2.5 fps (min) when the pipe is flowing full and the hydraulic gradient is equal to the slope of the pipe. This is will help carry sediment through the pipe system. And when not possible to achieve this velocity try to at least avoid a drop in velocity in the pipe system.
Connecting PVC pipe to existing storm sewer - not in a manhole 1
Oct 1, 2008 · Consult a concrete pipe manufacturer. Furnish and install one (1) 18" x 12" saddle, complete as specified, each. Furnish and install one (1) tap into existing 18" RCP storm sewer, complete as specified. Differential settlement is possible with a mortar joint; settlement may result in the pipe being sheared or cracked at the connection.
Tank drain flow rate and drain time calculations - Eng-Tips
Feb 12, 2009 · For comparison, yesterday I was draining one of our systems with a constant 1 or 2 ft of head through a 2" X 1' vertical steel pipe and the flowrate was 25-50 US gallons per minute. Through a 4" pipe this would be about 625 to 2500 gpm with only 2' of head. You might be a little low with your estimate.
Invert elevation and Rim elevation 1 - Eng-Tips
Jun 9, 2006 · Invert of the pipes in and out is the elevation at the bottom of the inside pipe wall, not the bottom of the pipe. Invert of the structure (MH or inlet) is the bottom of the inside of the structure, not the excavation depth. Engineering is the practice of the art of science - Steve
Basic question: Full pipe vs Partially filled pipe flow 9 - Eng-Tips
May 15, 2020 · Case-1. Water draining from washbasin to a drain pit (without a water seal). In this case, the flow from the tap is usually less than the sealing flow calculated for the drain pipe. If you examine the flow in the drainpipe, the flow of water will …
Stress Intensification Factors for Small Branch Connections
May 8, 2009 · What I predict is that the model will show an increase stress around the opening due to the stiffness increase introduced by the reinforcement weldolet and the geometry of the drain pipe. The SIF to account for built up stresses in the material adjacent to the opening should not be required since the stress disturbance in the material ...
Pipe Bedding layer: sand vs gravel - Foundation engineering
Aug 10, 2009 · That process has spelled doom for many leaves and dams where drain pipes, or other utility pipe had been laid within. To try to mitigate such flows, we will place permanent "ditch breakers" in the trench, which are sand cement sacks, poly foam, or other impermeable material, to act as water stops to try to dam the flows and avoid such ...
Truss Alteration, consequences in FL building code? 1 - Eng-Tips
Jan 22, 2006 · yup, it's a plumber special. truss is under the master bath (2nd flr) a piece was notched to give way for the drain pipe. the builder is refusing to issue a letter that certifies a fix/repair was done. there was an engineer recommendation on how to fix the truss however no assurance that it was done base from his recommendation.
Abandon an existing manhole - Waste disposal & treatment - Eng …
Nov 28, 2006 · I have used CALTRANS spec: 15?2.05A Frames, Covers, Grates, and Manholes? When existing manholes or inlets are to be abandoned, pipes entering the manhole or inlet shall be securely closed by a tight fitting plug or wall of minor concrete not less than 150-mm {0.5-foot} thick, or by a tight brick wall not less than 200-mm {0.67-foot} thick with cement mortar joints.