How to convert dBc to dBm? Thanks. | Forum for Electronics
Jan 31, 2009 · dbc to dbm dBm and dBc are completely different so there is no 'conversion' between the two. dBm - indicates the power measurement relative to 1 milliwatt. 0 dBm means no change from 1 mW, i.e. a power of exactly 1 mW. 3 dBm means 3 dB greater than 0 dBm. dBm is the relative difference to a fixed reference power of 1 mW.
Why do we use dBc/Hz as measurement unit? - Forum for …
Nov 26, 2006 · If you were comparing two CW tones it would be dBc. Comparing a tone to noise must be dBc/Hz. Also, it's in dB because it's easier to add than multiply. If you want to know the thermal noise power in a 1 kHz bandwidth is simply -174 dBm/Hz + 30 dBHz = -144 dBm.
How to measure SNR using Spectrum Analyzer? (dBc or dB)
Nov 7, 2020 · Since dBc means decibels relative to carrier, from the given Signal power(23.33 dBm) and SNR(58.75 dBc), you can derive Noise power which is -35.42 dBm. Then you can convert dBm to Watt which means Signal power = 215.278 mW and Noise power = 287.078 nW.
[cadence] plot waveVswave problem - Forum for Electronics
Jul 4, 2022 · IM3[dBc] VS Pout[dBm] Does work well on IM3[dBc] VS Pin(dBm), but IM3[dBc] VS Pout/(dBm) not working, I haven't been able to get this formula to work in any way.
What does "dBc/Hz" mean? Help newbie please - Forum for …
Feb 27, 2007 · u have -70dBc/Hz as u have center freq,. power 20dbm/Hz and 1st comp @ -50dBm/Hz , i.e,. the hole graph is dBm/Hz or dBm/Hz but if u subtract two powers then the result is in dB/Hz and if u refered any result to the carrier then the result will be dBc/Hz
What is the relation between dB AND dBm - Forum for Electronics
Jan 2, 2008 · add db and dbm values Hello All, dB or not dB? Everything you ever wanted to know about decibels but were afraid to ask… True or false: 30 dBm + 30 dBm = 60 dBm? Why does 1% work out to be -40 dB one time but then 0.1 dB or 0.05 dB the next time? These questions sometimes leave even experienced engineers scratching their heads.
how to plot antenna gain vs frequency in dbi using HFSS
Nov 6, 2014 · dbm, dbwm, dbc then how to plot in dbi, help me! Nov 13, 2014 #2 V. viper_iv Junior Member level 2. Joined ...
How to Convert dbc to db - Forum for Electronics
Mar 19, 2014 · lets give an example: unsigned 10 bit adc => so output is from 0 to 2^(10)-1. The maximum output value 2^(10)-1 is equall to 0 dBc. SNR is in log scale equall to Signal - Noise. Noise in dBc scale is always with '-' as it cant physically be greater then adc resolution ( max output), so SNR is always positive number.
OIP3 Calculation - Forum for Electronics
Jun 23, 2006 · When calculating OIP3, I use the equation OIP3, dBm = Pout, dBm + (0.5 * IM3, dBc ). Is Pout the powe 1670795113 When calculating OIP3, I use the...
convert noise figure V/sqrt Hz into dB | Forum for Electronics
Feb 19, 2013 · Dear all, Could anyone teach me how to convert noise value in V/sqrt Hz into dB? For example, if i have input noise= 9.758mV/sqrt Hz and output noise= 156.2pV/sqrt Hz, the bandwidth (cutoff freq)= 1.4354MHz, Then how i can convert the …