EMC Partner CN-BT7 - Single Turn Indirect Lightning Coupler
Rent the EMC Partner CN-BT7 injection probe with the AVI-3000 or AVI-LV3 systems designed for indirect lightning testing to MIL-STD-461 CS117 and DO-160 Section 22. The CN-BT7 is an ideal coupler for DO-160 Section 22 testing for indirect lightning requirements.
Requires CN-BT7 AVI3000 circuit: WF2 cable induction Standards DO-160G S22, MIL-STD-461G CS117, other Coupling mode Cable Induction (CI) Voltage waveform WF2 rise time: < 100 ns or < 340 ns selectable pulse duration: 6.4 µs ± 20 % Test level specified at coupler output Test level single stroke 25 V – 1600 V +20%, -0%
EMC Partner CN-BT7 Injection Probe - avalontest.com
Single turn injection probe for cable bundle testing according to MIL-STD-461 requirement CS117 and DO-160 section 22. For use with waveforms 1, 2, 3, 5A and 6 up to level 3 for DO-160.
EMC-PARTNER AVI3000 USER MANUAL Pdf Download | ManualsLib
4 Perform a test For WF6, connect the WF6-output on the generator with the CN-BT7 INPUT 1 using a 2 m HV-BNC cable. On the coupler, put the MC-bridge in the FILTER position. 3 Measurement Equipment Use a HV differential probe to …
EMC Partner AVI3000 - Rent MIL-STD & DO-160 Level 3 Generator
Includes CN-BT7 Injection Probe & TEMA3000 Software; Single stroke, multiple stroke and multiple burst events; Differential & Current Monitoring Probes Included
MIL-STD-461 CS117 - Rent Lightning Transients Generators
Rent lightning pulse/waveform generators for multiple burst & stroke testing for MIL-STD-461G CS117 including injection devices. Get fast deliveries on a variety of required equipment including the EMC Partner AVI3000 generator, LISNs, and monitoring equipment.
CN-BT7 | EMC PARTNER - Test Equipment
Single turn injection probe for cable bundle testing according to MIL-STD-461 requirement CS117 and DO-160 section 22. For use with waveforms 1, 2, 3, 5A and 6 up to level 3 for DO-160.
EMC Partner - Avalon Test
EMC PARTNER AG products are 100% designed and produced at our purpose built facility in Laufen, North West Switzerland. Their location ensures a ready supply of skilled workers and easy access to international airports. To produce a …
Lightning Current – Military - DO-160 - MIL-STD-461 - Jsdenki
DO-160 and MIL-STD-461G level 3 indirect lightning generator. All 6 waveforms for PIN, single/multiple stroke and multiple burst. Extensions for DO-160 / ED-14 WF6H, 0.224/4µs Impulse. 14 pulses Multiple Burst only. Coupling transformer for cable bundle test …
Lightning Voltage – Military - JS Denki
DO-160 and MIL-STD-461G level 3 indirect lightning generator. All 6 waveforms for PIN, single/multiple stroke and multiple burst. plug in to the MIG-OS-MB-EXT. Double exponential wave 0.1/6.4 for single pulse generation or first stroke of a multiple stroke sequence.